Shub Heats — Electric room heaters and immersion water | shubheats.com

Heater size for a 12 m² bedroom

Shub Heats — Electric room heaters and immersion water | shubheats.com

A 12 m² bedroom needs roughly 720-1,200 W of electric heat — 60-100 W for every square metre of floor, and more if the walls are uninsulated. Which type to buy depends on how fast you want the warmth and how long it should linger after switch-off.

Five electric heater types side by side — ratings and behaviour from published specifications
Heater typePower draw
Fan heater1,500-2,400 W
Oil-filled radiator1,500-2,500 W
Halogen heater400-1,200 W
Immersion water heater2,000 W
Frost-protection settingFraction of rated power

Terms worth knowing before you buy

Watt density (W/m²)
The sizing rule for electric heaters: 60-100 W of heater power per square metre of floor area. A 12 m² bedroom therefore needs roughly 720-1,200 W.
Kilowatt-hour (kWh)
The billing unit for electricity: 1,000 W running for one hour. A 2,000 W immersion heater running 30 minutes uses exactly 1.0 kWh.
Tip-over switch
A safety device that cuts power the moment a portable heater is knocked over. Standard on heaters shipped with a 13 A plug.
Thermal cut-out
An overheat switch that disconnects the element at roughly 120-150 °C element temperature, independent of the thermostat.
Frost-protection setting
A low thermostat mode that holds a room at 5-7 °C to stop pipes freezing, drawing only the fraction of rated power needed to maintain that floor.
Thermostat cycling
The behaviour of a heater after warm-up: it switches on and off to hold the set temperature instead of drawing full rated power continuously.

How many watts does a 12 m² bedroom need?

Roughly 720-1,200 W, at 60-100 W per square metre of floor area — more if the walls are uninsulated.

The sizing rule is simple multiplication: take the floor area in square metres and allow 60-100 W for each one. For 12 m² that gives a band of 720-1,200 W. A well-insulated room with modern windows sits near the bottom of the band; a draughty room with uninsulated walls sits at the top or above it.

Insulation is the single biggest correction. The same 12 m² bedroom in an uninsulated wall construction can need noticeably more than 1,200 W to hold temperature, which is why two identical-looking rooms can need different heaters.

Oversizing is tolerable because of the thermostat. A 1,500 W heater in a room that only needs 900 W will reach the set temperature and then cycle on and off instead of running continuously, so the average draw settles near what the room actually loses.

From cold start to steady state

Typical times for portable heaters rated between 400 and 2,500 W.

1-2 secondsA halogen element reaches radiant temperature and starts warming people and objects directly.5-10 minutesA fan heater moving 200-400 m³ of air per hour brings the room's air volume up to temperature.15-30 minutesAn oil-filled radiator brings its fins to about 60-90 °C and reaches full output.After warm-upThe thermostat starts cycling, so the heater no longer draws its full rated power continuously.Minutes after switchFan-heated air loses its warmth within minutes; oil fins keep releasing stored heat.
Timeline: 5 dated entries

Fan, oil or halogen — which type fits a bedroom?

For overnight bedroom use an oil-filled radiator is the steady choice; fan and halogen heaters solve different, shorter-term problems.

A fan heater rated 1,500-2,400 W moves 200-400 m³ of air per hour and warms a room in 5-10 minutes. The trade-off is retention: the warmth fades within minutes of switching off, so it suits a quick warm-up before bed rather than all-night heating.

An oil-filled radiator rated 1,500-2,500 W needs 15-30 minutes to bring its fins to about 60-90 °C, then holds the temperature by cycling on the thermostat. It is slower to start but steadier to sleep next to, with no fan forcing air around the room.

A halogen heater rated 400-1,200 W works by infrared: it warms people and objects within 1-2 seconds instead of heating the whole air volume. It is a spot heater — effective where you sit, not a way to raise the temperature of a whole bedroom.

The signature mark of this site, drawn as a plate

What it costs to run

Running cost is watts multiplied by hours multiplied by your tariff — nothing else enters the equation.

The arithmetic is fixed: 1,000 W running for one hour is 1.0 kWh. A 2,000 W immersion water heater running for 30 minutes uses exactly 1.0 kWh, which at a tariff of 0.15-0.30 USD per kWh costs 0.15-0.30 USD per use. The tariff varies by country, so the same heater costs twice as much to run in one place as in another.

A 2,000 W room heater at full power for one hour uses 2.0 kWh, or 0.30-0.60 USD at the same tariff range. A correctly sized 900 W average draw on a cycling thermostat costs less than half of that over the same hour.

Frost-protection mode is the cheapest way to keep an empty room safe: it holds 5-7 °C — just enough to stop pipes freezing — and draws only the fraction of rated power needed to maintain that floor.

  • Step 1 — find the rated watts on the heater's label, for example 2,000 W.
  • Step 2 — multiply by hours of use to get kWh: 2,000 W × 0.5 h = 1.0 kWh.
  • Step 3 — multiply kWh by your tariff, typically 0.15-0.30 USD per kWh depending on country, to get the cost per session.
The signature mark of this site, drawn as a plate

Spec table: heater types side by side

Five electric heater types side by side — ratings and behaviour from published specifications
Heater typePower drawTime to feel warmthWhat it heats bestWarmth after switch-off
Fan heater1,500-2,400 W5-10 minutes for room airWhole-room air, moved at 200-400 m³/hFades within minutes
Oil-filled radiator1,500-2,500 W15-30 minutes to fin temperature of 60-90 °CSteady, even whole-room heatThermostat cycles; fins release stored heat
Halogen heater400-1,200 W1-2 secondsPeople and objects in the infrared beamNone — radiant heat stops instantly
Immersion water heater2,000 WHeats water, not roomsWater in a tank or bucket1.0 kWh consumed per 30-minute use
Frost-protection settingFraction of rated powerMaintains rather than warmsEmpty rooms and exposed pipesHolds 5-7 °C continuously
Five electric heater types side by side — ratings and behaviour from published specifications

Where the numbers come from

Figures are drawn from manufacturer ratings for portable heaters, the EU space-heater energy label rescale of March 2021, and standard 230 V electrical arithmetic.